Specifications
PhD
5
Miscellaneous Accessories
PART NO. DESCRIPTION
13-092 PhD
5
Reference Manual.
13-093 PhD
5
Quick Reference Card.
22-130 PhD
5
training video.
22-131 PhD
5
interactive training
CD-ROM.
42-005 Shoulder strap for PhD
5
.
45-016 Leather weather cover for
PhD
5
.
56-282 Leather weather cover for
PhD
5
with TouchID
™
.
PhD
5
Calibration Materials and
Carrying Cases
PART NO. DESCRIPTION
54-27-0401 Case for Value Pack. Foam-
lined case, with room for
1 compact sized calibration
gas cylinder.
35-0002 Case for Confined Space Kit.
Foam-lined, waterproof
Pelican
™
style case with room
for one standard sized
calibration gas cylinder.
54-27-0501 Calibration kit for PhD
5
.
Includes foam-lined carrying
case with room for up to three
cylinders of calibration gas.
Kit contains 12-023 regulator
and other fittings. Kit does not
include gas.
54-27-V9045 Value Pack “Make-up” Kit.
Includes Value Pack case with
54-9045E calibration gas and
12-022 regulator
. F
or use with
O
2
/ LEL; O
2
/ LEL / CO and
O
2
/ LEL / CO+ configurations.
54-27-V9047 V
alue Pack “Make-up” Kit.
Includes Value Pack case with
54-9047E calibration gas and
12-023 regulator
. F
or use with
O
2
/ LEL / H
2
S conf
igurations.
54-27-V9049 Value Pack “Make-up” Kit.
Includes V
alue Pack case with
54-9049E calibration gas and
12-023 regulator. For use with;
O
2
/ LEL / CO / H
2
S and O
2
/
LEL / Duo-T
ox (CO / H
2
S)
configurations.
10-263 Sample draw / calibration
adapter for PhD
5
.
54-05-A0409 Calibration adapter for use
with reactive gases (NH
3
,
Cl
2
, ClO
2
, HCN, NO
2
).
PhD
5
Multi-Gas Detectors
PhD
5
Smart Sensors
P
ART NUMBER DESCRIPTION RANGE RESOLUTION
54-25-80A LEL Combustible gas 0 – 100% LEL 1% LEL
54-04-90 O
2
Oxygen 0 – 30% / Vol. 0.1%
5
4-25-01
C
O Carbon Monoxide 0 – 1000 PPM 1 PPM
54-25-05 CO+ CO Plus dual purpose CO/H
2
S CO: 0 – 1000 PPM 1 PPM
(provides a non-specific H
2
S: 0 – 200 PPM 1 PPM
r
eadout for CO and H
2
S
)
54-25-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
to H
2
54-25-02 H
2
S Hydrogen Sulfide 0 – 200 PPM 1 PPM
54-25-14 Duo-Tox Dual Channel CO/H
2
S CO: 0 – 1000 PPM 1 PPM
(provides substance specific H
2
S: 0 – 200 PPM 1 PPM
readouts for CO and H
2
S)
54-25-03 SO
2
Sulfur Dioxide 0 – 25 PPM 0.1 PPM
54-25-15 SO
2
-Ext. Sulfur Dioxide extended range 0 – 100 PPM 1 PPM
54-25-04†NH
3
Ammonia 0 – 50 PPM 1 PPM
(for software versions
prior to 2.0)
54-25-21† NH
3
Ammonia 0 – 100 PPM 1 PPM
54-25-08† †† Cl
2
Chlorine (non-specific) 0 – 50 PPM 0.1 PPM
54-25-18† †† Cl
2
Chlorine (specific) 0 – 50 PPM 0.1 PPM
54-25-12† †† ClO
2
Chlorine Dioxide (non-specific) 0 – 15 PPM 0.1 PPM
54-25-20 ClO
2
Chlorine Dioxide (specific) 0 – 5 PPM 0.01 PPM
54-25-06 NO Nitric Oxide 0 – 350 PPM 1 PPM
54-25-09†NO
2
Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
54-25-10† HCN Hydrogen Cyanide 0 – 100 PPM 0.2 PPM
54-25-13 PH
3
Phosphine 0 – 20 PPM 0.1 PPM
† Special reactive gas calibration adapter (54-05-A0409) required for proper calibration.
††
The non-specif
ic Cl
2
and ClO
2
sensors can be used for the detection of both gases.
The specif
ic Cl
2
and ClO
2
sensors are designed for the target gas only
.
22