Specifications

PART NUMBER PHD
5
SENSORS INSTALLED A AC N NC AV
5
4-24-30321
L
EL / O
2
/
SO
2
/
NH
3
••••
54-24-30305 LEL / O
2
/ SO
2
/ CO+
••••
54-24-30308 LEL / O
2
/ SO
2
/ Cl
2
(non specific)
••••
54-24-30309 LEL / O
2
/ SO
2
/ NO
2
••••
54-24-30310 LEL / O
2
/ SO
2
/ HCN
••••
54-24-30312 LEL / O
2
/ SO
2
/ ClO
2
(non specific)
••••
54-24-30313 LEL / O
2
/ SO
2
/ PH
3
••••
54-24-30318 LEL / O
2
/ SO
2
/ Cl
2
(specific)
••••
54-24-30319 LEL / O
2
/ SO
2
/ CO-H
••••
54-24-30320†‡ LEL / O
2
/ SO
2
/ ClO
2
(specific)
••
54-24-30321 LEL / O
2
/ SO
2
/ NH
3
54-24-30800 LEL / O
2
/ Cl
2
(non specific)
••
54-24-30821 LEL / O
2
/ Cl
2
(non specific) / NH
3
••••
54-24-30809 LEL / O
2
/ Cl
2
(non specific) / NO
2
54-24-30810 LEL / O
2
/ Cl
2
(non specific) / HCN
54-24-30813 LEL / O
2
/ Cl
2
(non specif
ic) / PH
3
••••
54-24-30815 LEL / O
2
/ Cl
2
(non specific) / SO
2
-Ext.
••••
54-24-30819 LEL / O
2
/ Cl
2
(non specific) / CO-H
••••
54-24-30900 LEL / O
2
/ NO
2
••••
54-24-30921 LEL / O
2
/ NO
2
/ NH
3
••••
54-24-30910 LEL / O
2
/ NO
2
/ HCN
••
54-24-30912 LEL / O
2
/ NO
2
/ ClO
2
(non specific)
••••
54-24-30913 LEL / O
2
/ NO
2
/ PH
3
••••
54-24-30915 LEL / O
2
/ NO
2
/ SO
2
-Ext.
••••
54-24-30918 LEL / O
2
/ NO
2
/ Cl
2
(specific)
••••
54-24-30919 LEL / O
2
/ NO
2
/ CO-H
54-24-30920†‡ LEL / O
2
/ NO
2
/ ClO
2
(specific)
••
54-24-31000 LEL / O
2
/ HCN
••••
54-24-31012
LEL / O
2
/ HCN / ClO
2
(non specific)
••••
54-24-31015 LEL / O
2
/ HCN / SO
2
-Ext.
••••
54-24-31018
LEL / O
2
/ HCN / Cl
2
(specif
ic)
••••
54-24-31019 LEL / O
2
/ HCN / CO-H
••••
54-24-31020†‡ LEL / O
2
/ HCN / ClO
2
(specific)
Continued on Page 21
The non specific Cl
2
and ClO
2
sensors can be used for the detection of both
gases. The specific Cl
2
and ClO
2
sensors are designed for the target gas only.
The ClO
2
specif
ic conf
iguration is not available in kits and requires the use of
a calibration gas generator
.
Alkaline
Alkaline CSK
NiCad
NiCad CSK
Alkaline Value Pack
Battery and/or Kit Configuration (CSK = Confined Space Kit)
PhD
5
Remote Accessories
PART NO. DESCRIPTION
54-27-0101 Continuous sample pump
for PhD
5
, slip-on. Includes
10' tubing and sample probe
assembly.
54-27-0101-C Continuous sample pump for
PhD
5
, slip-on – Configured for
reactive gas detection, such as
Cl
2
and ClO
2
. Includes 10' of
inert tubing and sample probe
assembly.
54-27-0102 Continuous sample pump
for PhD
5
, screw on. Includes
10' tubing and sample probe
assembly.
54-27-0102-C Continuous sample pump for
PhD
5
, screw-on – Configured
for reactive gas detection, such
as Cl
2
and ClO
2
. Includes
10' of inert tubing and sample
probe assembly.
35-0344 Tubing kit for reactive gas
detection (Cl
2
and ClO
2
).
Includes 10' of tubing plus
adapters.
54-05-A0401 Sample draw kit for PhD
5
.
Includes adapter, squeeze
bulb, 10' of tubing and
sample probe assembly.
Not for use with Cl
2
and ClO
2
.
54-05-A0403 Sample probe assembly. Does
not include tubing, squeeze
bulb, or sample draw adapter
54-05-A0405 Sample probe assembly with
11.5-inch stainless-steel probe
tube. Does not include tubing,
squeeze bulb, or sample draw
adapter.
10-263 Sample draw/calibration
adapter for PhD
5
.
PhD
5
Multi-Gas Detectors
PhD
5
Configuration
20