Owner's Manual

945P-A7G/945PL-A7G
9
CP U FEAT UR E
Delay Prior to Thermal
Set this item to enable the CP U Thermal function to enga ge after the specified t ime.
The Choices: 4Min, 8Min, 16Min (default), 32Min.
The rmal Ma nage me nt
Allow you to choose the thermal management method of your monitor.
The Choices: Thermal Monitor 1 (default), Thermal Monitor2.
Notes: The cho ices will be different according to your CPU features.
TM2 Bus Ratio
Represents the frequency. Bus ratio of the throttled performance state that will be
initiated when the on-die sensor goes from not hot to hot.
Min= 0, Max= 255, Key in a DEC number.
The Choices: 0X (default).
TM2 Bus VID
Represents the voltage of the throttled performance state that will be
initiated when the on-die sensor goes from not hot to hot.
The Choices: 0.8375V (default), Min=0.8375V, Max=1.6000.
Limit CPU ID MaxVa l
Set limit CPU ID maximum vale to 3, it should be disabled for Win XP.
The Choices: Disabled (default), Enabled.