User manual

16
Power Supply
48V battery charging procedure (power supply)
Connect the power supply and the battery by
inserting the charge connector into the TOUCH PORT
– the BionX system can be on or off
Connect the power supply to a power receptacle
The battery TOUCH PORT (LED ring around the
charge connector) lights up red upon insertion and
then turns to amber during the charging process
When fully charged, the colour of the LED ring
changes to green. The battery charging process is
then complete
• Following this procedure the charging connector should be disconnected from the battery
• During the charging process you can check the battery state-of-charge through the console if the
battery is connected to the system – a 48V system can be switched on while it is charging
This has my vote :)
Battery state-of-charge Colour
100-75 % Green
75-20 % Amber
< 20 % Red
Checking the 48V Battery state-of-charge
• Swipe your finger slowly over the TOUCH PORT
• Battery state-of-charge LED will illuminate
• Allow ten (10) seconds before checking state-of-charge again
NOTE
The power supply is suitable for line voltage ranges of 110-115V or 220-230V, and com-
pensates automatically. The 48V battery is designed to be charged by a 26V BionX power
supply. The battery has an integrated charger which permits the use of a small, portable
power supply.
Ensure that a completely charged battery is no longer connected to the power supply after the charge
procedure is completed.
TOUCH PORT green =
fully charged
TOUCH PORT amber =
charging
TOUCH PORT red =
upon insertion
english