CAUTIONS BEFORE INSTALLATION
NOTE THE FOLLOWING IMPORTANT POINTS
1. Do not install in a location where water might be splashed on this appli-
ance or in a location exposed to excessive moisture where condensation
might form on the product’s surface.
2. To avoid damage to electronic components due to high levels of humidi-
ty, provide adequate ventilation by opening a window
and/or door when bathing.
3. Water supply should have a water pressure of 0.07 MPa to 0.74 MPa.
4. Connect the product to a pipe carrying potable water. Do not connect to
an industrial water line or other water supplies that are not potable.
5. Bring the unit to room temperature.
6. The thermal protector in the water tank may
malfunction when transporting or storing warm water.
7. The rated power voltage in AC 120V, 60Hz
8. Do not plug the unit in, until installation is complete.
It may result in malfunction.
WIRING REQUIREMENTS
1. After installation, all other servicing should be performed by authorized
service representatives.
2. Grounding Instructions - This product should be grounded. In the event
of an electrical short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This product is
equipped with a cord having a grounding wire and grounding plug. They
must be plugged into an outlet that is properly installed and grounded.
DANGER - Improper use of the grounding plug can result in a risk of
electric shock.
If it is necessary to repair or replace the cord or plug, do not connect the
grounding wire to a flat blade terminal. The grounding wire can be iden-
tified by its insulated outer surface. It will either be colored green or will
not contain yellow stripes.
Check with a qualified electrician or serviceman if you do not
understand grounding instructions or if you do not know whether
the product is properly grounded.