Instruction manual
69
System Operation
Figure 28. Programming: the Fraction Collector’s Windows Mode
(Screen displays are keyed to the discussion in Table 20)
Window Start (ml) End (ml) Frac (ml)
>01 0.00 to 60.0 5.00
02 New collection window to be added
INSERT EDIT DELETE OK
Window Start (ml) End (ml) Frac (ml)
01 0.00 to 60.0 5.00
>02 New collection window to be added
ADD OK
Method: Volume: 1.00 ml
Window: 1 Start: 0.00 ml
End: 0.00 ml
(start) END CANCEL OK
Method: Time: 1.00 ml
Window: 1
Fraction Size: 1.00 ml
CANCEL OK
Method: Volume: 1.00 ml
Select a Fraction Collector Mode
ALL THRESHOLD WINDOWS THRES+WIN
F1
F4
F4a
F4b
(return
to FT)
(return
to FT)
(return
to F4)
(return to F4)
(return to F1)
F4a
FRACTION COLLECTION TABLE FOR WINDOWS MODE
START AND END TIMES FOR WINDOW
F4b
FRACTION SIZE FOR WINDOW
F4
LEGEND: WINDOWS MODE
To remove Method's fraction collection
mode; no fraction collection will occur
when the Method is run.
Method: name Volume: 2.00 ml
FC Mode: Collect all
Estimated Number of Fractions: 20
EDIT ERASE NEW MODE OK