Specifications
28
The significance of Intelli-Marks and how they are used
The Intelli-Marks are circular targets with a unique segmented ring-like bar code that is
automatically recognized by the ETemplate software process.
Wall Markers
Edge Markers
The two types of Intelli-Marks are Intelli-Mark stickers and Intelli-Mark Edge Markers. The
stickers are normally placed along the wall surfaces. The Intelli-Mark Edge Markers are
placed flat or standing on the ends/faces of the cabinets for all necessary profiles.
In addition to these two Intelli-Mark
types, you will also use Intelli-Mark
scales, which provide accurately
specified measurements.
Intelli
-
Scale
The following table shows the effects of temperature on the 46.00” aluminum scales. All materials are affected by
temperature. These scales have been designed to minimize changes due to temperature variations. When you are
in an environment with fairly extreme temperatures, it is a good practice to measure the scale to verify how it may
have varied. As you can see from the table below, temperature has only a minimal effect on the scale length. In
the vast majority of templates this will not affect your process. For large templates during extreme temperature,
you may want to measure the scale. When measuring the scale, be sure to measure from center of marker to
center of marker. When you do find small changes in the scale length, use the new value in the scale/constraint
functions.
Scale Temperature Measurement Affect
90 degrees + .016 inches (1/64)
80 degrees + .008 inches
70 degrees no change
60 degrees -.008 inches
50 degrees -.016 inches (1/64)
40 degrees -.024 inches
30 degrees -.032 inches (1/32)