Specifications
15
∗
To visually check constraint point IDs open a Point Table and sort
(SORT column by clicking in column header) the Constraints column. All
Point IDs defined as Constraints will have a 1 in the column. There will
always be twice as many ID rows with 1s as the number of constraints.
(column should only show 0s or 1s)
How To View Selected Point Table items:
•
Select all constraint point IDs and right mouse click | click Open
Photos Showing Selected
Or
•
If all photos are opened and tiled to the workspace, select
Expand selection to all Windows and Close the Point Table
The Selected point(s) will be highlighted red in the photos (this
technique can be used to visually check for misreferenced
constraint points)
5. Check the highest value of the LARGEST RESIDUAL (pixels)
Sort LARGEST RESIDUAL (pixels) column 2 times
Check that the Highest value <.80
Follow up if necessary, to reduce the highest Largest Residual
points to less than .80 and re-process and save