User's Guide
This document is subject to change without prior notification.
Binsfeld Engineering Inc. | 231-334-4383 www.binsfeld.com 869610-9_A2 Pg. 15
2.2.10 Power Consumption
The following table shows typical power supply current draw for the
stream mode.
Table 7, TX20K current draw, stream mode, 250K baud, 5000 sps
Power
Supply (Vdc)
Power supply current draw (mA) at the four RF power
levels
1
2
3
4
6.0
33
36
39
43
8.0
26
28
30
33
12.0
21
22
24
26
20.0
19
20
21
22
2.2.11 Battery Life
Below are typical battery life times for the different operating modes of
the TX20K. The 2 batteries listed are an Ultralife 9V Lithium battery and
a standard 9V Alkaline battery. The battery capacities used for the
calculations are 1200mAh for the lithium and 550mAh for the alkaline.
These values are with a 350
Ω gage connected and at and RF Power
level of 1. Actual battery life times can vary depending on battery type,
age, charge state, RF power level, gage resistance and operating
environment.
Table 8, TX20K battery life
Mode
Baud
Sample
Rate
RF
Power
Level
Average
Current
(mA)
Lithium
Battery
(hours)
Alkaline
Battery
(hours)
Stream
250K
5000
1
28
43
20
Block
250K
5000
1
26
46
21
Block
250K
500
1
21
57
26
Block
250K
50
1
21
57
26
Standby
250K
5000
1
0.36
3300
1500