Programmer Owner manual

24
IQ
®
Programmer Reference Manual
AI3: The EN Input is not used for Alarm
Reset and may be used as a
general purpose input. AI will be
automatically set to 3 if CM is set
to 13, 14, 17, or 18 or if SI is set to
either 1 or 2 after the AI command is
set.
AI1
A B C
A
Input is open, normal operation
B
Input closed, alarm is reset
C
D
Alarm occurs
time
A B C
D
time
A
Input is closed
B
Input opened, no reset occurs
C
Input closed, alarm is reset
D
Alarm occurs
E
AI2
A B C
A
Input is closed, normal operation
B
Input opened, alarm is reset
C
D
Alarm occurs
time
A B C D
time
A
Input is open
B
Input closed, no reset occurs
C
Input opened, alarm is reset
D
Alarm occurs
E
(high)
(low)
(high)
(low)
(high)
(low)
(high)
(low)
Input opened, drive is re-enabled
D
Input opened, drive is re-enabled
E
Input closed, drive is re-enabled
D
Input closed, drive is re-enabled
E