Upright
1) Cross the two feet (7) and fasten them to the fixed rod (9) using the 4 screws provided, cover the
joint between the feet and the fixed rod using the cover (5).
2) Lengthen the adjustable rod (10) to the required height and lock tightly using the rod fixing ring
nut (4).
Ventilator
3) Insert the handle (11) in the motor casing so the 4 pins enter the corresponding slots. The handle
must be positioned correctly (upwards and towards the back part), otherwise the grid cannot be
fastened.
4) Fasten the rear grid (16) to the motor casing, positioning the corresponding pins and holes, and
lock using the appropriate ring nut (15).
5) Insert the fan (17) on the motor shaft (1) and lock with the appropriate ring nut (13) turning it
tightly anti-clockwise.
6) Couple the front grid (12) with the rear grid (16) and lock with the plastic ring and ensure the
fastening with the appropriate locking screw (14), (the screw must be in the lower part). Having
done this, check that the protection grid is firmly coupled and fastened to the motor.
7) Fasten the fan to the upright, inserting the lower hole on the adjustable rod of the upright. Make
sure that the fastening holes correspond: the passage is close to the feed cable, the nut screw (for
fastening) is more or less at the top of the rod. Lock the special metric screw (18) in the holes
describe and tighten normally. Cover the hole with the plug provided.
USE
Before each use, make sure the electric cord is in good condition.
Insert the plug of the fan in the power supply.
Ventilation: select the desired speed by turning the switch (8) to one of
the following positions:
1– Minimum speed 2–Medium speed 3–Maximum speed
To turn off, turn the switch to position 0 and then remove the plug from
the socket.
Horizontal oscillation (right-left): this is selected with the button (2) located on the motor body.
To stop the motion and keep the ventilator still, press the button.
Vertical inclination (high-low): it is regulated by gripping the motor body and orienting it in the
direction desired.
When not in use for long periods, the plug must always be removed from the socket.
CLEANING AND MAINTENANCE
Attention: before normal cleaning, remove the plug from the socket.
Ensure that the fan is switched off from the supply mains before removing the guard (12).
Clean the body with soft, slightly damp, cloth; do not use abrasive or corrosive products.
Do not immerse any part of the fan in water or other liquid: if this should happen, do not put your
hand in the liquid, but first remove the plug from the socket. Carefully dry the appliance and
make sure that all the electrical parts are dry: in the case of doubt, ask for professionally qualified
help.
It is essential that the motor's air holes be kept from dust and lint.
Periodically check the electric cord for damage; its replacement requires a special tool: contact an
authorized service center, also for any repairs.
If the fan will not be used for long periods, it must be protected from dust and humidity; we