• Make sure that the fan heater is working correctly: if not, turn the heater off and have it checked by
professionally qualified personnel.
• Make sure that the air-intake grid is not obstructed by objects, fabrics or anything else to avoid the
heater overheating or breaking.
• Do not use the appliance with a timer or a programmer or with a system that can switch on the
appliance automatically, to avoid risk of fire, since a fire risk exists if the heater is covered or
positioned incorrectly. Check that no other high absorption appliances are connected to the same
power source.
• In the case of a breakdown or fault, switch off the appliance and have it checked by a
professionally qualified technician; repairs made by unqualified persons can be dangerous and
render void the warranty.
USE
Before each use, verify that the unit is in good condition, the electric cord is not damaged, if the
power cord is damaged, it must be replaced by the manufacturer or a competent qualified electrician
or a person with similar qualifications, in order to avoid any risk.
mod. S314 basic version (Fig.1)
The fan-heater is fitted with switch, thermostat, Ionising function and left-right oscillation:
- the switch sets following functions:
“0”= OFF; “
”= fan; “I”= = air warm (1000W); “I I”= air very hot (2000W)
- the thermostat sets the room temperature, that will be higher if the knob is rotated to position max
clockwise: when the temperature is reached, it will be kept uniform
- Ionising function: this produces a flow of negative ions which neutralise the positive ions in the air;
the ionising function is less evident in environments with high levels of humidity, this fuction is On
then is selected the button (B)
- left-right oscillation: switch on the key for the swinging (TURN) to let the stove swing to the left
and to the right.
To use the thermofan, please follow the instructions below:
1) Insert the plug in the current socket: the pilot light on, comes on indicating the presence of
voltage.
2) Turn the thermostat knob clockwise to the position corresponding to the desired temperature:
3) To switch the appliance on, turn the selector knob (D) to the position corresponding to the
desired function.
4) If desired, select the “TURN”(A) and ionizing”IONIC” (B) functions using the buttons.
5) To turn the appliance off, rotate the knob to position “0” and take the plug out of the socket.
Never leave the appliance connected to the socket if it is not in use, especially for long periods.
Mod. S315 with 24 hour programmer (Fig.2)
The appliance has a switch, a thermostat and a 24 hour programmer, Ionising function and left-right
oscillation. The functions of the switch and thermostat are described in the previous paragraph; the
programmer permits fan heater “on” and “off” periods to be set during a 24 hour period, and of
repeating them systematically, day-after-day.
The programmer is active when the button (F) on its side is aligned with the ”
” symbol; if it is
aligned with the “I” symbol, the programmer is excluded.
To use the fan heater, act as described in points 1 and 2 of the previous paragraph. Also:
a) Operating with the programmer excluded (button pos. “I”).
a1) Turn the switch to line up with position “I” or “I I”; the appliance comes on as does the luminous
pilot light.
a2) To switch off the appliance, turn the switch to pos. “0” (the pilot light goes out) and remove the
plug from the current socket.