B–4000 Instant Boiling and Ambient Filtered Water System Installation guide
Installation requirements. water tubing deleted for clarity 150mm minimum clearance 15 mm stop-tap (installed by plumber) 135mm power outlet 60mm minimum clearance 192mm —Determine unit location Plan the installation. Dispenser tube lengths, position of power and water outlets, required air space around the underbench module and access for service must be considered before cutting tube lengths. Refer to Diagrams 1, 2 and 3 for clearances around the dispenser and unit.
Installing dispenser. —IMPORTANT This Billi appliance is to be installed by a licensed tradesperson in accordance with AS 3500.4 or AS/NZ 3500.4.2 and in compliance with applicable state regulatory requirements. For correct operation of this appliance, it is essential to observe the manufacturer’s instructions. —Plan dispense position Determine the position of dispenser mounting hole in sinktop or benchtop. Refer to Diagram 2 for clearances allowed.
—For continued safety of this appliance it must be installed, operated and maintained in accordance with the manufacturer’s instructions. —Install underbench unit Take care to observe minimum clearances. Ensure there is adequate access to service the unit. —Connect dispenser tubing and electrical plug Connect all tubing and electrical plug as shown in Diagram 8 and 9. Ensure correct orientation of dispenser power plug before insertion.