Installation guide
Isis
®
WWW.BIGASSFANS.COM ©2011 DELTA T CORP. DBA BIG ASS FAN CO. ALL RIGHTS RESERVED
30
Basic Light Switch
WHT
100~125VAC 1Ф
10A 60Hz
EXISTING SWITCH 
BOX ON WALL
BLK
GRN
Bare Cu GND
BASIC 2-WIRE (plus ground) Lighting Circuit
Limited access application
CAUTION: The fan must operate on a dedicated 
circuit with a dedicated neutral. Failure to install 
the fan on a dedicated circuit will cause the fan 
to operate improperly.
Illustrated on the right is a typical lighting circuit with 
one basic light switch. The fan operational critical 
red conductor or “traveler” conductor is absent. For 
Isis fan applications in which installing a 3-wire plus 
ground circuit (black, white, and red) is impractical or 
impossible, an optional limited access fan controller 
can be installed to eliminate the required red traveler 
conductor between the controller and the fan, allowing 
the utilization of the existing 2-wire plus ground circuit 
(black and white) shown below.
Note: This scenario is common in residences in which 
only a light circuit was previously installed.
Typical Lighting Circuit
Note: It is essential that the speed controller and remote controller are 
installed on a common branch circuit. The control signal between the 
devices is modulated on the shared hot conductor and may be absorbed 
at the breaker panel if this rule is not followed. This wiring method 
should have been noted at the time of order. If not, contact Big Ass Fans 
Customer Service.
Basic 2-Wire (Plus Ground) Single Fan Application
Alternative Wiring Methods
To order optional wiring kits, see the Optional Parts Order Form.
FAN SPEED 
CONTROLLER
Companion Module
WHT
100-125VAC 1Φ
10A 60Hz
MOUNTED IN 
EXISTING SWITCH 
BOX ON WALL
BLK
GRN
RED (not used)
WHT
BLK
GRN
RED
Bare Cu GND
Fan wire functions / colors:
AC Hot / Black
Neutral / White
Traveler / Red
FAN SPEED 
CONT. REMOTE
Fixture Module
MOUNTED 
LOCAL TO FAN 
IN CEILING 
JUNCTION BOX
- Status LED
2475D22475D2