MOUNTING STRUCTURE: COLUMN
WARNING: The fan should not be installed unless the structure on which the fan is to be mounted is
of sound construction, undamaged, and capable of supporting the loads of the fan and its method of
attachment. Verifying the stability of the mounting structure is the sole responsibility of the customer and/
or end user, and Big Ass Fans hereby expressly disclaims any liability arising therefrom, or arising from
the use of any materials or hardware other than those supplied by Big Ass Fans or otherwise specified in
these installation instructions.
CAUTION: It is your responsibility to comply with all local and national codes and regulations regarding
mounting procedures and installation height!
The safety cable must be installed if mounting the fan to a column.
Yellow Jacket
®
can be mounted to a column that is part of the existing building structure. The following instructions
are merely a recommendation for mounting the Yellow Jacket on a column. Consult a structural engineer to
determine the best method for mounting your fan.
1. Prepare angle irons
Note: All hardware (including angle irons) used to secure the wall/column mount supports is installer-supplied.
Big Ass Fans cannot provide specific installation details because of the wide variability of mounting surfaces,
conditions, and fastening methods. Consult a structural engineer to determine the required hardware.
Cut each angle iron to the appropriate length using the width of the column, round or flanged (flange or open-
flange side), as a reference.
Drill a Ø9/16” hole on each end of the angle iron 3/4” (1.9 cm) from the edge of the column. Refer to the table and
illustration below. Repeat the above process on all angle irons.
Angle Iron Requirements
Column mounting application Minimum angle iron dimensions (W x H x T) Number of angle irons needed
Flanged Column (Flange Side)* 2.5” x 2.5” x 0.25” (6.4 cm x 6.4 cm x 0.64 cm) 4
Flanged Column (Open Flange Side)* 2.5” x 2.5” x 0.25” (6.4 cm x 6.4 cm x 0.64 cm) 8
Round Column 2.5” x 2.5” x 0.25” (6.4 cm x 6.4 cm x 0.64 cm) 2
*Refer to the diagram below.
Note: Exact installation may dier from the illustration.
Flanged Column Diagram
Angle Iron Diagram
Flange Side
Column
Open Flange Side
3/4”