Specifications

Trunks 43
© 2003-2008 Bicom Systems
Qualify:
The qualify command is a time sensitive function that sends a request packet to verify the status of the
device. As long as SWITCHware receives an "ACK" (Acknowledge) Packet from the devices, the trunk is
will be considered to be online. However, if the device does not reply with an "ACK" Packet within the
specified period of time (in milliseconds), the device is considered to be offline for future calls. The
Default Value is set to "8000" (milliseconds)
National Dialing Code:
This is national dial code needed to be dialled in order for system to be able to dial national destinations
using this trunk.
Example: "1" (USA, Canada), "0" (United Kingdom, Germany)
Leave National Code:
Includes national code when dialing a number.
Available options:
·
Yes
·
No
·
N/A
International Dialing Code:
This is the international dial code needed to be dialled in order for system to be able to dial international
destinations using this trunk. Example: "1" (USA, Canada), "00" (United Kingdom, France)
E164 Accepted:
If trunk supports accepting destinations in E164 format.
Prefix:
Value entered in this field will be included before the destination number dialed:
Example:
Prefix= "5"
Dialled destination"212 400 7921"
system will dial: 9 212 400 7921"
Outbound Caller ID:
This field sets default outbound Caller ID for every call where caller ID is already not set.
6.1.1.1.2 Authentication
Authentication section allows trunks to store and use values from various fields in order to communicate with
service providers.