Hardware manual
Issue 8 Electra Elite
2 - 12 System Specifications
4.3.2 Power Supply Consumption
The power consumption for the Electra Elite 192 system
is listed in Table 2-8 Power Consumption.
Table 2-8 Power Consumption
4.3.3 Fuse Replacement
When replacing fuses, refer to the specifications in Table
2-9 Fuse Replacement.
KSU
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic KSU – B64-U10 KSU 2.5 A 120 230
Basic KSU + Expansion KSU 5.0 A 240 460
Basic KSU + 2 Expansion KSUs 7.5 A 360 690
Table 2-9 Fuse Replacement
Unit
Fuse
Number
Specifications Description Dimensions
P64-U10 PSU F1 125V, 6.0A AC Input 1/4” x 1 1/4”
P64-U10 PSU F101 250V, 10A Battery Input 1/4” x 1 1/4”
All fuses are normal blown glass tube.
Do not use slow blow fuses. Replace with a fuse o
f
the same type and rating.