Hardware manual
System Hardware Manual 10 - 1
System Maintenance Chapter 10
SECTION 1
I
NTRODUCTION The technician can use this chapter to troubleshoot and diagnose
problems during and after system installation. The troubleshooting flow
charts and general test procedures aid the technician to identify possible
causes of the problem by defining the problem area.
Using the System Data Upload/Download feature, all System
Programming and Speed Dial data can be stored on disk for safe keeping.
After all System Programming is completed, it should be downloaded to a
disk for backup. If system memory fails, this data on the disk can be
uploaded and the memory restored.
SECTION 2
O
PERATIONAL
C
URRENT AND
V
OLTAGE CHECKS
The effectiveness of this maintenance section depends on the technician.
Due to external factors, the technician should not make any assumptions.
For example, donāt assume that a new power supply used to replace
another power supply is working properly. Check the output of the power
supply with a volt meter.
The ESI(8)-U10 ETU allows the measurement of +5V and ā24V. This ETU
can be used in the expansion KSU for the power output measurements.
Refer to Table 10-1 Voltage Measurement. Before the technician can
troubleshoot, the correct tools must be available. Some of these are listed
below.
Digital or Analog Multimeter that can read DC and AC current and
voltage and DC Resistance.
Test Set (lineman) that has termination and monitor modes and
DTMF and DP dialing.