3.16 Connecting a KSU to a Personal Computer
To use the Automatic Call Distribution (ACD), Least Cost Routing
(LCR), Wireless, and PC Programming, specialized software must
installed in the user PC and the PC must be connected via a serial
port to the KSU.
3.16.1 Connecting the PC to the KSU
Using RS-232C straight cable, connect the PC to one of
the COM ports on the side of the KSU. Refer to Figure
7-66 Connecting a PC to the KSU.
The functions and the communication port connections
are:
Serial-port characteristics include:
Function Port
Least Cost Routing (LCR) COM 1
PC Programming COM 1
Wireless Programming COM 1
Station Message Detail
Recording (SMDR)
COM 2
Automatic Call
Distribution (ACD)
COM 4
Characteristic Value
Baud Rate
38.4 K
(maximum)
Parity None
Stop Bit 1 stop bit
Data Bit 8 bits