Hardware manual

Issue 8 Electra Elite
5 - 152 Installing Electronic Telephone Units
7.9.3 Switch Settings
S1
Reset Switch
S2
Eight position DIP switch.
Refer to Table 5-69 MG(8)-U( ) ETU S2 Switch
Settings.
Table 5-69 MG(8)-U( ) ETU S2 Switch Settings
S2 Description Default
1
ETU Type Selection. Refer to Table 5-70 ETU Common
Settings for the IAD platform
2
3
4
Four/eight channel Assignment: On: 8 channel, Off: 4
channel
On
5 On to Enable 1st Power On On
6 Default IP Address Setting On/Off Off
When MG(8)-U10 ETU is booted with Switch 6 On, the following defaults are set:
MG IP Address Assignment: 192.168.0.2
MG Subnet Mask Assignment: 255.255.255.0
MG Router Address Assignment: 0.0.0.0
DHCP Client Assignment: Disable
7
On to output Log data for system communications.
Used for troubleshooting.
Off
8
On to output Log data for MEGACO.
Used for troubleshooting.
Off