2. To connect an Expansion KSU, use the two screws
to attach the FG plate to the Basic and Expansion
KSUs. Refer to Figure 4-26 Attaching the Frame
Ground Plate. (When installing a second Expansion
KSU, another FG plate is required.)
3.10.2 Grounding Requirements
The KSUs must be properly grounded. The Electra Elite
KSUs are provided with a typical AC third-wire ground. If
this ground is questionable, an alternative ground must
be provided.
1. Connect the grounding cable (green wire) to the
ground terminal on the right side of the Basic KSU.
The locally provided grounding cable AWG must be
greater than #16.
Figure 4-26 Attaching the Frame Ground Plate
FG Plate