Datasheet

UPSI-2403
24 V DC / 6 A
Continuous battery monitoring
Battery capacitance display
Battery lifetime display
USB communication interface
The UPSI-2403 protects connected consumer loads from supply
voltage fluctuations and interruptions. Made for DIN-Rail
mounting the μC controlled DC UPS has a continuous battery
monitoring which ensures that sufficient capacitance remains in
the battery to guarantee the supply of consumer loads in case of
power failure. Additionally the UPSI-2403 offers a load sensor and
a timer function.
Input voltage 24 V DC (22.5…28 V)
Input current 6.7 A max.
Output voltage In normal mode: app. 0.5 V below input voltage
In battery mode: app. 29…19 V DC
Output current 6 A max.
Battery charge current 0.65 A max. (internal battery charger)
Charging method UI characteristic, with temperature regulation
Protection Deep discharge protection: 19 V DC ±2 %
Overload protection at output: 9 A for 2 seconds, switch off
Short-circuit protection: Switch off via µC
Transfer time / limits Mains / battery 20 V DC ±2 %, battery / mains 22 V DC ±2 %
Interface USB (Standard B)
Type of battery Equipped lead-gel-battery, maintenance-free, 1.3 Ah
Safety / EMC CE
Temperature Operating: 0…+40 °C / Storage: -10…+40 °C
Humidity Operating: 10…85 % RH, non-condensing / Storage: 10…90 % RH, non-condensing
Dimensions (W x D x H) 90 x 100 x 121 ±0.5 mm
Weight (net) 2 kg
Product specific data
LED display 3-colour-LED for „Power ok” (green), „Power Fail” (orange), „Battery low” (red/orange flashing) and
„Battery defect” (red/green flashing), short circuit at output/overload (red)
Battery monitoring Battery test is carried out in normal mode approx every 10 minutes, in case of “Battery defect“ notification
the LED flashes red/green
Power consumption App. 80 mA
Shutdown detection Via UPS Software „UPSI Control Center“
Shutdown-suppression During system start-up the shutdown signal is suppressed for app. 2 minutes.
Reboot function If power fails and then returns during the shutdown mode of Windows®, the operating system will ‚lock‘ with
the message Your PC is now safe“. The reboot function restarts the system after about 10 seconds.
Load sensor Adjustable via UPS software „UPSI Control Center
Timer function Adjustable via UPS software „UPSI Control Center“ in 2 minutes-step from 2…20 min.
Back up time App. 33 min at 1 A / app. 9 min at 3 A / app. 3.5 min at 5 A (measured at +20 °C)
UPS software „UPSI Control Center“ (Windows® XP or higher) to download at www.bicker.de
The service life of the batteries is app. 4…5 years at +20 °C and will decrease by half with each temperature increase of 10 °C according to EUROBAT.
Te c h n i c a l d a t a
Operation
Operation
Delivery
5
YEARS
Delivery
5
YEARS
Fanless
Fanless