User manual

Operating instructions
Accessories for industrial power modules
Product: PSZ-1010, EMC lter module for PCB mounting
Intended use
The lter module attenuates conducted electromagnetic interference and thereby improves the EMC characteristics of the BEN power modules
(e.g. improvement from class A to class B according to EN 55022, depending on application). The module must be soldered to a printed circuit board
(PCB mounting). Only a qualied technician may install this unit.
Safety instructions
Attention, danger of life! The lter module is for PCB mounting. Contact with the input or output pins of the soldered lter module may cause
an electric shock! The following safety label is to be axed to the cabinet: „Before opening the cabinet, pull the mains plug!“ It is strictly
forbidden to modify, open, disassemble or reconvert the lter module! Any use other than described in these operating instructions may
damage the lter module and cause dangers such as short-circuit, re etc.!
In case of damages due to disregard of these operating instructions any warranty will expire. Bicker will not be responsible for any consequential
damages! We refuse any responsibility for damages to property or persons due to inappropriate handling or disregard of these operating
instructions. Any warranty will expire!
Technical data
Before using this lter module, be sure to read the data sheet. If it is unavailable, you can read or download it in the internet on www.bicker.de. Here
you will nd important information such as input voltage, output rating, operating temperature, derating, connection of earth conductor and more.
The lter module may not be operated outside of these technical data!
Installation and start-up
Only a qualied technician may install this unit. During installation the respective standards regarding electrical safety as well as the standard
EN 60950 have to be observed. Before soldering the lter module, power-o the unit by disconnecting the power plug from the lter module.
The lter module is a built-in unit and may preferably be used inside a metal housing. The end device must comply with the current EMC standards.
It is also recommended to use short cables between the module and the load.
The lter module is a product according to Protection Class I. When installing the lter module, ensure a secure protective conductor connection
from the power module to the metal housing (via circuit board). The leakage current should not exceed 3,5 mA. During installation ensure that the
lter module is adequately ventilated. Free circulation of air has to be possible. Also make sure that the ventilation slots are not covered by objects,
assembly parts or ribbon cables.
Operation
The lter module may only be operated in dry interiors. Contact with water, even by condensing air humidity, has to be avoided under any
circumstances. Operation under conditions such as extreme cold or heat, in a dusty environment and near inammable gases, steams or solvents is
strictly forbidden as well. Always ensure an adequate ventilation.
Maintenance
The lter module does not contain any parts which need maintenance.
In case of failure, switch-o the lter module and pull the main plug.
Repairing is not possible due to the encapsulated construction.
These operating instructions are a publication of Bicker Elektronik GmbH, Ludwig-Auer-Straße 23, D-86609 Donauwörth.
Errors, mistakes as well as modications of engineering and equipment are reserved. © 04.07.2013 by Bicker Elektronik GmbH
Disposal
Electrical and electronic devices may not be
disposed o with domestic waste! At the end
of its useful life, dispose of the product
according to the respective legal regulations.
Bicker Elektronik GmbH | Ludwig-Auer-Straße 23 | 86609 Donauwörth | Germany
Tel. +49 906 70595-0 | Fax +49 906 70595-55 | info@bicker.de | www.bicker.de