User manual

29
English
User’s Manual IUPS-401-Series
Status display and Alarm
Status display Alarm Alarm sound LED
detachable
Normal UPS mode green
Battery charge (mains mode) green flashing
UPS battery mode 2 beep sounds every 3 seconds yes red flashing
UPS battery mode (Battery low) 4 beep sounds a second no red flashing (quickly)
Overload (Normal mode) Continuous sound no red
Internal UPS failure 8 beep sounds per 2 sec., no red flashing (quickly)
2 sec. stillness
Overtemperature 8 beep sounds per 2 sec., yes red flashing (quickly)
2 sec. stillness
Battery defect red flashing (quickly)
Model overview
Article Interface Load sensor UPS management software
No. switch off
IUPS-401 USB 33 W
IUPS-401-B5 USB 20 W
IUPS-401-BB USB ≤ 8 W
IUPS-401-BC USB ≤ 0 W
Reboot function
If mains voltage returns after a power failure while Windows® is already shutting down, the UPS
switches the PC off (after the shut-down period) and switches it on again after approximately
30 seconds (observe BIOS settings of mainboard).
UPSilon 2000 and internal USB cable
included in delivery (WIN 98, NT, 2000,
2003, XP, ME, Vista, 7, Novell NetWare®,
LINUX, FreeBSD, others on request).
External USB cable 2.0, A-/B-plug / 500
mm included in delivery.
Article Interface Load sensor UPS management software
No. switch off
IUPS-401-B1 SERIAL (D-SUB) 33 W
IUPS-401-B4 SERIAL (D-SUB) 20 W
IUPS-401-BA SERIAL (D-SUB) ≤ 8 W
IUPS-401-B9 SERIAL (D-SUB) 0 W
Reboot function
RUPS 2000 OEM, UPS management
software included in delivery.
If mains voltage returns after a power failure while Windows® is already shutting down, the UPS
switches the PC off (after the shut-down period) and switches it on again after approximately 5
seconds in conjunction with RUPS 2000 and an ACPI-PC (observe BIOS settings of mainboard).