User manual

Operating instructions
Industrial PC PSUs with direct-current voltage input (DC)
Models: BES-540C, BES-540T, BES-560T, BES-630C, BES-630V, BES-640C, BES-640T,
BES-640P, BEP-506C, BEP-510C, BEH-630C, DPSM-6500F-B1
Intended use
This PC power supply is used for providing power to a computer or to PC components such as main board, hard disk, CD-Rom etc. It is a built-in
unit and therefore has to be installed in a metal housing. Only a qualied technician may install this unit.
Safety instructions
Attention, danger of life! It is strictly forbidden to modify, open, disassemble or reconvert the PC power supply! The models BEP-506C
and BEP-510C are open-frame power supplies. Contact with the components may cause an electric shock! The following safety label is to be
axed to the PC cabinet: „Before opening the cabinet, pull the mains plug!“ Any use other than described in these operating instructions
may damage the PC power supply and cause dangers such as short-circuit, re etc.!
In case of damages due to disregard of these operating instructions any warranty will expire. Bicker will not be responsible for any consequential
damages! We refuse any responsibility for damages to property or persons due to inappropriate handling or disregard of these operating
instructions. Any warranty will expire!
This is a class A* device (industrial area). This device may cause radio interference in residential areas.
In that case the operator can be asked to take appropriate measures.
Technical data
Before using this PC power supply, be sure to read the corresponding data sheet. If it is unavailable, you can read or download it in the internet under
www.bicker.de. Here you will nd important information such as input voltage, output rating, operating temperature, derating and more. The PC
power supply may not be operated outside of these technical data!
Installation
Only a qualied technician may install this unit. During installation the respective standards regarding electrical safety as well as the standard
EN 60950 have to be observed. Before installation, power-o the unit by switching it o or pulling the main plug
.
* The PC power supply is an built-in unit and may only be used inside a metal housing. The housing must ensure a minimum screening attenuation
of 30 dB. For the installation of the PC power supply suitable screws according to data sheet have to be used.
The PC power supply is a product according to protection class I. During installation a secure connection of the grounding equipment conductor
between power supply and metal housing has to be ensured (due to EMC causes). Cables should be run neatly and straight. Make sure the cables are
not squeezed or damaged. Protect cables against sharp edges in the housing. If necessary, x them using cable straps and apply a protective padding
to sharp edges. Make sure the cables do not get into the computer fan. During installation ensure that the PC power supply is adequately ventilated.
Free circulation of air has to be possible. Also make sure that the ventilation slots are not covered by objects, assembly parts or ribbon cables.
Operation
The PC power supply may only be operated in dry interiors. Contact with water, even by condensing air humidity, has to be avoided under any
circumstances. Operation under conditions such as extreme cold or heat, in a dusty environment and near inammable gases, steams or solvents is
strictly forbidden as well. Always ensure an adequate ventilation.
Connection to the supplying DC source
Please ensure correct polarity and correct input voltage rate. First connect
the negative source connector
(Minus) with the
of the input socket of
the PC power supply. Then you connect the positive
+
(Plus) connectors.
Make sure the cable cross section is sucient and use suitable cable lugs.
We recommend to provide the conductor with an additional fuse.
Derating
When operating the PC power supply in a higher temperature range such as +50…+70 °C the power drain has to be reduced in order to decrease
the load applied to the unit. This is not done automatically. The user himself has to take this into consideration when setting up the system and allow
for an adequate power reserve!
Example: If a 300 Watt PC power supply has to be operated at +60 °C operating temperature and a derating of 1 % / °C within the range of
+50…+70 °C is dened in the data sheet, the output load may not exceed 270 Watts.
Maintenance
The PC power supply does not contain any parts which need maintenance.
In case of failure, switch-o the PC power supply and pull the main plug.
Repairing und therefore opening of the PC power supply has to be done
by a qualied technician or repair shop.
These operating instructions are a publication of Bicker Elektronik GmbH, Ludwig-Auer-Straße 23, D-86609 Donauwörth.
Errors, mistakes as well as modications of engineering and equipment are reserved. © 18.12.2012 by Bicker Elektronik GmbH
Disposal
Electrical and electronic devices may not be
disposed o with domestic waste! At the end
of its useful life, dispose of the product
according to the respective legal regulations.
Bicker Elektronik GmbH | Ludwig-Auer-Straße 23 | 86609 Donauwörth | Germany
Tel. +49 906 70595-0 | Fax +49 906 70595-55 | info@bicker.de | www.bicker.de
DC PC PSU Min. cable cross section
at 1 m feed wire
BES-540C, BES-540T, BES-560T 4 mm
2
BES-630C, BEH-630C 4 mm
2
BES-640C, BES-640T, BES-640P 4 mm
2
BES-630V 2x 4 mm
2
BEP-506C, BEP-510C 1,5 mm
2
DPSM-6500F-B1 4 mm