Datasheet
Ripple and Noise was measured with parallel cables (1 µF ceramic capacitor + 10 µF electrolytic capacitor). All data was measured at +25 °C, operating humidity <75 %, nominal input voltage. The
final assembly has to comply with the valid EMC and safety standards.
We recommend to use a cable as short as possible to connect module and load. As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition.
Input voltage 85…264 VAC, 120…370 V DC
Input frequency 47…63 Hz
Input current 110 VAC 230 VAC
BEN(D)-05 120 mA, typ 70 mA, typ
BEN(D)-10 260 mA, typ 160 mA, typ
BEN(D)-20 600 mA, typ 340 mA, typ
BEN(D)-40 1000 mA, typ 600 mA, typ
BEN(D)-60 1400 mA, typ 700 mA, typ
Inrush current 110 VAC 230 VAC
BEN(D)-05 10 A, typ 20 A, typ
BEN(D)-10 10 A, typ 20 A, typ
BEN(D)-20 16 A, typ 30 A, typ
BEN(D)-40 30 A, typ 50 A, typ
BEN(D)-60 30 A, typ 50 A, typ
Hold up time >80 ms (typ / 230 VAC), >15 ms (typ / 115 VAC)
Leakage current 0.3 mA (typ / 230 V AC / 50 Hz)
Voltage accuracy ± 2%
Load fluctuation ± 1%
Minimum load BEN(D)-05/10/20/40: 0 %, BEN(D)-60: 1 %
Trim ± 10 % Trim of output voltage for the following models possible:
BEN(D)-20/40/60
Protection Short circuit protection: Switch off with auto recovery
Overcurrent protection: 110…150 %, switch off with auto recovery
Overvoltage protection: 5 V models: ≤7,5 VDC
12 V models: ≤20 V DC
15 V models: ≤20 V DC
24 V models: ≤30 V DC
BEN(D)-60: Zener diode
Back-up fuse must be used! For calculation/type, please refer to the application notes.
Insulation voltage Input / Output BEN(D)-05/10/20/40: 3000 VAC/1 Min, BEN(D)-60: 4000 VAC/1 Min
Input / FG 1500 VAC/1 Min
Output/FG 500 VAC/1 Min
Insulation resistance Input / Output and Input / FG 100 MΩ (min)
Safety / EMC EN60950-1, UL60950-1, CE
Protection class BEN(D)-05/10/20/60: Protection class I
BEN(D)-40: Protection class II
Temperature Operating: -30…+70 °C / Storage: -40…+85 °C
Derating BEN(D)-05/10/20 –30…–10 °C: 2.0 % / °C, +55…+70 °C: 3.75 % / °C
BEN(D)-4005/6005 +45…+70 °C: 3.0 % /°C
BEN(D)-4012/4015 +55…+70 °C: 3.7 % / °C
BEN(D)-4024/6024 +55…+70 °C: 2.7 % / °C
BEN(D)-6012/6015 +50…+70 °C: 2.5 % / °C
MTBF BEN(D)-05/10/20: >300000 h according to MIL-HDBK-217F at +25 °C
BEN(D)-40/60: >200000 h according to MIL-HDBK-217F at +25 °C
Max. operating altitude 2000 m
Humidity Operating: 10…85 % RH, non-condensing / Storage: 10…90 % RH, non-condensing
Switching frequency 65 kHz (typ), BEN-60: 100 kHz (typ)
Dimensions (W x D x H) See drawing
Weight (net) BEND-05/10/20: app. 0.2 kg, BEND-40/60: app. 0.4 kg
BEN-05/10/20: app. 0.1 kg, BEN-40/60: app. 0.3 kg
Te c h n i c a l d a t a
Optional accessory For detailed information please visit our website www.bicker.de and refer to the article number.
Article No. Description
PSZ-1009 Male adapter, DC plug on screw terminal
Bicker Elektronik GmbH | 86609 Donauwörth | Germany
Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Power supplies