Datasheet
Ripple and Noise was measured with parallel cables (1 µF ceramic capacitor + 10 µF electrolytic capacitor). All data was measured at +25 °C, operating humidity <75 %, nominal input voltage. The 
final assembly has to comply with the valid EMC and safety standards. 
We recommend to use a cable as short as possible to connect module and load. As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. 
 Input voltage  85…264 VAC, 120…370 V DC
 Input frequency  47…63 Hz
 Input current    110 VAC  230 VAC
   BEN(D)-05  120 mA, typ  70 mA, typ
   BEN(D)-10  260 mA, typ  160 mA, typ
   BEN(D)-20  600 mA, typ  340 mA, typ
   BEN(D)-40  1000 mA, typ  600 mA, typ
   BEN(D)-60  1400 mA, typ  700 mA, typ
 Inrush current    110 VAC  230 VAC
   BEN(D)-05  10 A, typ  20 A, typ
   BEN(D)-10  10 A, typ  20 A, typ
   BEN(D)-20  16 A, typ  30 A, typ
   BEN(D)-40  30 A, typ  50 A, typ
   BEN(D)-60  30 A, typ  50 A, typ
 Hold up time  >80 ms (typ / 230 VAC), >15 ms (typ / 115 VAC)
 Leakage current  0.3 mA (typ / 230 V AC / 50 Hz)
 Voltage accuracy  ± 2%
 Load fluctuation  ± 1%
 Minimum load  BEN(D)-05/10/20/40: 0 %, BEN(D)-60: 1 %
 Trim  ± 10 % Trim of output voltage for the following models possible:  
   BEN(D)-20/40/60 
 Protection  Short circuit protection: Switch off with auto recovery
   Overcurrent protection: 110…150 %, switch off with auto recovery
   Overvoltage protection:   5 V models: ≤7,5 VDC
     12 V models: ≤20 V DC
      15 V models: ≤20 V DC
     24 V models: ≤30 V DC
     BEN(D)-60: Zener diode
   Back-up fuse must be used! For calculation/type, please refer to the application notes.
 Insulation voltage  Input / Output  BEN(D)-05/10/20/40: 3000 VAC/1 Min, BEN(D)-60: 4000 VAC/1 Min
   Input / FG  1500 VAC/1 Min 
   Output/FG  500 VAC/1 Min
 Insulation resistance  Input / Output and Input / FG 100 MΩ (min) 
 Safety / EMC  EN60950-1, UL60950-1, CE
 Protection class  BEN(D)-05/10/20/60: Protection class I
   BEN(D)-40: Protection class II
 Temperature  Operating: -30…+70 °C / Storage: -40…+85 °C
 Derating  BEN(D)-05/10/20  –30…–10 °C: 2.0 % / °C, +55…+70 °C: 3.75 % / °C
   BEN(D)-4005/6005  +45…+70 °C: 3.0 % /°C
   BEN(D)-4012/4015  +55…+70 °C: 3.7 % / °C
   BEN(D)-4024/6024  +55…+70 °C: 2.7 % / °C
   BEN(D)-6012/6015  +50…+70 °C: 2.5 % / °C
 MTBF  BEN(D)-05/10/20: >300000 h according to MIL-HDBK-217F at +25 °C
   BEN(D)-40/60: >200000 h according to MIL-HDBK-217F at +25 °C
 Max. operating altitude  2000 m
 Humidity  Operating: 10…85 % RH, non-condensing / Storage: 10…90 % RH, non-condensing 
 Switching frequency  65 kHz (typ), BEN-60: 100 kHz (typ)
 Dimensions (W x D x H)  See drawing  
 Weight (net)  BEND-05/10/20: app. 0.2 kg, BEND-40/60: app. 0.4 kg
   BEN-05/10/20: app. 0.1 kg, BEN-40/60: app. 0.3 kg
Te c h n i c a l   d a t a
  Optional accessory    For detailed information please visit our website www.bicker.de and refer to the article number. 
  Article No.  Description
 PSZ-1009  Male adapter, DC plug on screw terminal
Bicker Elektronik GmbH  |  86609 Donauwörth  | Germany
Tel.   +49 906 70595-0  |  info@bicker.de |  www.bicker.de
Power supplies 