Datasheet
Bicker Elektronik GmbH | 86609 Donauwörth | Germany
Tel. +49 906 70595-0 | info@bicker.de | www.bicker.de
Power supplies
More performance classes and ATEX certified PSUs are available on request.
Ripple and Noise was measured with parallel cables. All data was measured at +25 °C, operating humidity <75 %, nominal input voltage. After the PowerBoost, the device must not be operated
over the max. output power for at least 60 seconds. The final assembly has to comply with the valid EMC and safety standards. As a power component this PSU is for assembly purposes only and
must not be operated in unassembled condition. The case in which the BED3P is installed must be at least IP54 compliant.
Explosion hazardous voltages are currently present for up to 5 minutes after switching off the BED3P. The device must not be touched during this time period. Remove device only when it is
de-energized and not in a hazardous area. Risk of explosion!
Input voltage Nominal: 3x 400…500 VAC / 500 VDC
Range: 3x 320…600 VAC (3 Phase), 2x 380…600 VAC (2 Phase) / 450…800 VDC
Power factor correction (PFC) Active PFC
Input frequency 50…60 Hz
Input current <1,7 A / 3x 400 VAC, <1,4 A / 3x 500 VAC
Inrush current <40 A (at 3x 400 VAC or 3x 500 VAC)
Nominal output voltage 24 VDC
Output voltage adjustment range 24…28 VDC (max. load ≤960 W)
Line regulation <0,5 % typ.
Load regulation <1 % typ.
Hold up time >20 ms (at 3x 400 VAC or 3x 500 VAC / 100 % load)
Rise time <100 ms at nominal voltage (100 % load)
Start-up time <1500 ms at nominal voltage (100 % load)
Protection Short circuit protection: Hicc-up-Mode (with auto recovery after error correction)
Overload/-current protection: >150 % of rated current, Hicc-up-Mode (with auto recovery)
Overtemperature protection: +65 °C (depending on load and while operating in the
derating range, the over-temperature protection can
trigger already below +65 °C), Hicc-up-Mode (with auto
recovery)
Overvoltage protection: >28.8 V, SELV-Output, Hicc-up-Mode (with auto recovery)
Insulation voltage Input / Output 4000 VAC
Input / FG 2000 VAC
Output / FG 1500 VAC
Safety EN60950-1, UL60950-1, UL 508, CE
Designed according to CSA C22.2 No. 60950-1 and CSA C22.2 No. 107.1-01
EMC CISPR22, EN55022, CISPR11, EN55011, FCC: Class B
IEC 61204-3 (Low-voltage power supply devices, DC output)
Designed according to SEMI F47
Earth leakage current <3,5 mA (typ)
Temperature Operating: -25 °C…+65 °C (Cold start from -40 °C) / Storage: -40 °C…+85 °C
Derating >50 °C: 2,5 % / °C
MTBF >300000 h according to Telcordia SR-332 at +25 °C
Max. operating altitude 2000 m (UL508), 2500 m (UL/EN60950-1)
Humidity Operating: 10…90 % RH, non-condensing / Storage: 10…90 % RH, non-condensing
Vibration test (non-operating) Designed according to IEC60068-2-6, 10...500 Hz at 30 m/s
2
(max. 3G); 60 min per axis (X, Y, Z)
Shock test (non-operating) Designed according to IEC60068-2-27, 30G (300m/S²) for 18 ms
Protection class IP20
Dimensions (W x D x H) 255.0 x 117.3 x 121.0 mm
Weight (net) 2.6 kg
Te c h n i c a l d a t a
DIN Rail PSU