Specifications

13
LSI-16 SPECIFICATIONS
Life Safety Interface 16 SPECIFICATIONS
System Fault Relay:
Type:
Load:
Maximum operating voltage:
Maximum operating current:
Maximum switching capacity:
Minimum permissible load:
Single ‘Form C’ voltage-free
SPST change-over contact
Resistive
125VAC, 60VDC
600mA AC, 1A DC
37.5VA, 30W
10µA @ 10mVDC
RS232 Port
Type:
Baud Rate:
DTE
57600
Connection: RJ45 with shielded Ethernet/PoE cable
(CAT5, CAT5e, CAT6, or CAT7)
Parallel Control Inputs:
Number:
Type:
Cathode presented at input –
pull low to enable. Sink Current:
Min:
Max:
Maximum Terminal Voltage:
Isolation:
Eight
Opto Isolator LED
1mA
6mA
24V
3kV
Power:
Main:
PoE:
24V DC 15W
802.3af Class 3
Base Dimensions:
Height:
Width:
Depth:
1.75 inches (44.5mm)
19 inches (483mm)
10 inches (254mm
Parallel Control Outputs:
Number:
Type:
Maximum Continuous Current:
Current Limit:
Maximum External Supply:
VMon Input Shutdown:
Eight
FET switch, open drain
(low side driver)
0.35A
0.8A
35V
35V
Weight: Approx 6.4 lbs. (2.8kg)
Ambient Operating
Temperature Range: 32-113 degrees F (0-45 degrees C)
Compliance: EU Directive 2002/95/EC, RoHS directive
CE marked
Life Safety Interface 16 BLOCK DIAGRAM
LEDs
Vocia System
control data
24V DC
PoE
Control Inputs
Control Outputs
Option Slot
ID Switches
HostProcessor
585.0245.90A