Vocia® VO-4e Operation Manual January 2013 Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this product near water. 6) Clean only with dry cloth. 7) Do not block ventilation openings. Install in accordance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other product (including amplifiers) that produce heat.
TABLE OF CONTENTS VOCIA OUTPUT 4 UNIT WITH EXTENDED CAPABILITY (VO-4e) . . . . . . . . . . . . . . . . . 4 FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FRONT PANEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VOCIA OUTPUT 4 WITH EXTENDED CAPABILITY (VO-4e) The VO-4e is an enhanced networked audio output expansion device that allows the user to add four line-level and CobraNet® output channels to be added to a Vocia system. The VO-4e can be configured for Channel-to-Channel or Device-to-Device failover and uses comprehensive fixed-chain digital-signal processing within the device, including volume control, ducking, equalization, compressor/limiter, speaker crossover, delay, and output gain.
VO-4e FRONT PANEL Setup and Use The Vocia software provides the interface for configuring and programming the VO-4e. The information supplied by this manual relates to hardware installation, physical connections, device and channel failover concerns. For more details on software setup, please consult the Vocia Software Help File.
VO-4e REAR PANEL Connections All numbered audio, relay and power connectors on the rear panel of the unit are configured with the lowest output or input on the left of the connector as viewed from the rear of the unit. Auxiliary Power Caution - Due to potential energy hazard, connections to the Auxiliary Power 24V DC inputs must be made by a qualified electrician or other qualified person as required to conform with all local codes. Dual 24V DC power inputs are provided on a four-way 0.2” (5.
VO-4e REAR PANEL CobraNet LED indication Left LED Right LED Description None None No Data Connectivity or CobraNet activity None Flashing green Network Link established. Typically seen on Secondary port when acting as a failover to the Primary connection. Yellow Flashing green Network Link established. Typically seen on Secondary port when acting as a failover to the Primary connection.
VO-4e REAR PANEL Amp Fault Imputs Four amplifier Fault Inputs are provided via a six-way 0.2” (5.08mm) pluggable screw terminal block. These allow for fault monitoring of the output of the VO-4e as indicated from an external amplifier. By default each input allows an external voltage-free contact closure to ground to indicate a fault condition for the corresponding VO-4e Output channel. Inputs are pulled high internally to create a default non-asserted condition.
VO-4e REAR PANEL Failover Modes Device-to-Device or Channel-to-Channel failover modes are supported. Only one type of failover mode can be implemented per device. Device-to-Device Failover VO-4e units provide for Device-to-Device failover when a fault is detected. A Failover Link Cable must be connected between the primary and the redundant units as shown below.
VO-4e SPECIFICATIONS Vocia Output 4e SPECIFICATIONS Message Memory: Network Audio: Network Connections: Nominal Output Level: Maximum Output Level: Maximum Output Load: Dynamic Range: Frequency Response: THD + Noise (20Hz-10kHz): Power: PoE: Aux Voltage Nominal: Fault & Control Input Ports: Assert: Un-assert: Input Impedance: Max. short circuit current: 5.
VO-4e WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below.
FCC COMPLIANCE FCC NOTICE - CLASS B DIGITAL DEVICE NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential as well as in a commercial environment.
COMPLIANCE DoC VO4E201203 EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. Any alterations to the product not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration.
COMPLIANCE EU RoHS COMPLIANT This Biamp product, including all attendant cables and accessories supplied by Biamp, meets all requirements of EU Directives 2011/65/EU of 8 June 2011, the EU RoHS Recast. An EU RoHS Materials Content Declaration document may be obtained at www.biamp.com The following information is presented to comply with Chinese law SJ/T11363-2006.