Tesira® TEC-1s & TEC-1i Operation/Installation Manual October 2012 Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.
TABLE OF CONTENTS TESIRA ETHERNET CONTROL (TEC-1) FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . 3 FRONT PANEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Setup and Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Display. . . . . . . . . . . . . . . . . . . . . . . . .
TESIRA ETHERNET CONTROL (TEC-1) TEC-1 Tesira Ethernet Control is a remote control for Tesira systems. It offers a simple, intuitive interface for end users and can be installed and configured to fit the unique needs of a particular application. The device connects via standard Ethernet cabling and is powered over Ethernet, eliminating the need for custom cabling and local power sources. Multiple remote control panels can be connected over large distances using standard network technology.
TEC-1 FRONT PANEL Select Scroll Latch Setup and Use The Tesira software provides an intuitive interface for setup and programming of the TEC-1. The information supplied by this manual relates to physical connections and device setup. For more details on software setup, please consult the Tesira Help File. Display A graphic OLED (Organic Light-Emitting Diode) display with white characters on a black background shows a list of all control items available from that panel, as well as the last selected item.
TEC-1 BACK PANEL Connectors Two Ethernet connectors—one rear-facing RJ45 and one top-facing insulation displacement connector (IDC)—are provided for connecting to the network. Only one connector may be used. The RJ45 and IDC utilize unshielded twisted pair (UTP) wiring to connect to a Tesira system. This connection is made to the Ethernet port of a Tesira unit, either directly (single station) or via a network switch, and carries control data over Ethernet. The TEC-1 is powered using IEEE 802.
TEC-1 SET UP Device Setup Mode The TEC-1 can be configured without connecting to a functional Tesira network. To enter setup mode, connect the TEC-1 to a PoE source and place the jumper or any metal object across the locksmith pins. When configuration is complete, remove the jumper and attach it to only one pin to resume normal operation. Please note: many of the configuration settings can be accessed via the Tesira software.
TEC-1 SET UP Edit Device ID To name the unit, scroll to the ID Tag icon and press the Select button. Use the scroll wheel and Select button to select the desired characters. Scroll to the icon and select it to delete the previous character. The default Device ID is “TEC-1ID 01”. The Device ID must match that of a corresponding block in the Tesira design. More than one unit may be identified with the same design block (same ID). Device IDs may also be assigned via Device Maintenance in the Tesira software.
TEC-1 SET UP Edit Unlock Code To set password protection, scroll to the Key icon and press the Select button. Use the scroll wheel and Select button to choose the desired characters. During normal operation, holding down the Select button for five seconds will lock the unit, and the user will be prompted for the Lock Code before obtaining access. Lock Codes may also be assigned via Device Maintenance in the Tesira software.
TEC-1 SET UP View Device Information To view information regarding the specific unit, scroll to the Information icon and press the Select button. The Serial Number, MAC Address, Firmware Version, Hostname, IP Address, network mask, and gateway are displayed. This is non-editable information. The Serial Number is helpful in identifying physical units/locations when naming them via Device Maintenance in the Tesira software.
TEC-1s INSTALLATION Surface Mount Installation The TEC-1s surface mounts to most walls and has a wide variety of mounting holes that accommodate standard US and international back boxes. 84mm 3.3" USA, Japan, Australia 60mm 84mm 2.36" 3.3" EUR Italy including Germany, Sweden, UK, Netherlands Use a screw driver or other suitable tool to engage the latch at the bottom of the TEC-1s to detach the back enclosure.
TEC-1i INSTALLATION Flush Mount Installation The TEC-1i may be flush mounted using the retrofit plate (provided with the product) or a Raco® 254 box (purchased from an electrical distributor). To install the TEC-1i, a hole must be cut in the wall to accommodate the Raco 254 box or to use the retrofit plate. See the figures below. 11.75cm 4 5/8″ 4 3/4″ 12.
TEC-1i INSTALLATION Retrofit Plate Raco 254 box Trim Ring Front Plate Exploded view showing pieces required for mounting to the retrofit plate or the Raco 254 box When installing the TEC-1i using the retrofit plate or the back-box, fasten the trim ring using the four screws provided to either the retrofit plate or the back-box.
TEC-1 INSTALLATION Connect the wire according to the color code silkscreened as text next to the IDC or as shown on the label on the back enclosure (see figure below). The color code uses the T568A standard for wiring. When using the T568B wiring scheme, please note that the orange wire pair (OR and WH/OR) and green wire pair (GR and WH/GR) need to be swapped. After inserting the wires, press the tabs until the insulation is punctured with an audible click. No wire stripping is necessary.
TEC-1 SPECIFICATIONS TEC-1s SPECIFICATIONS Dimensions: 5.1”H x 4.7”W x 1.25”D (130mm x 120mm x 32mm) Weight: 0.5 lb (0.2kg) Power consumption: PoE Class 1 (3.
WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. Biamp Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized Biamp Systems dealer, subject to the terms and conditions set forth below.
FCC COMPLIANCE FCC NOTICE - CLASS B DIGITAL DEVICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in either a residential or commercial installation.
EC DECLARATION OF CONFORMITY DoC TEC-201205d EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that our delivered version the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. Any alterations to the product not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration.
COMPLIANCE EU RoHS COMPLIANT This Biamp product, including all attendant cables and accessories supplied by Biamp, meets all requirements of EU Directives 2002/95/EC of January 27, 2003, and 2005/618/EC of August 18, 2005, the EU RoHS Directives. An EU RoHS Materials Content Declaration document may be obtained at www.biamp.