Specifications

11
SETUP
BUTTON DEFINITION SCREEN
The Button Definitions screen is used to assign specific actions to remote control buttons. Although the NMP200 does not accept wall-
mount (WMC) or infrared (IR-T) push-button remote controls directly, an accessory unit (RT) is available, which can translate these control
buttons into RS-232 commands. The NMP200 can also receive echo characters (via RS-232) from other ADVANTAGE
®
products which
are
utilizing these types of push-button remote controls. From the factory, Remote Control Buttons have equivalent ASCII characters
permanently assigned to them (see RS-232 Control on pg. 14). Therefore, a Remote Control Button can be assigned specific actions,
which the NMP200 will then perform whenever the equivalent ASCII character for that button is received. From the factory, Remote
Control Buttons have no pre-programmed functions. However, using the Button Definitions screen, each Remote Control Button may be
assigned various actions. Remote Control Buttons
selects which button is to be defined. Actions can then be assigned to the selected
Remote Control Button in the same way they are assigned to Logic Inputs (see Logic Input Definition Screen on previous page). Clear
allows all actions assigned to the selected Remote Control Button (or all Remote Control Buttons) to be cleared. Help
provides additional
instruction. Close
will close the Button Definition screen.