Specifications

11
APPLICATIONS
50/60 Hz
~
27V
12 watts
class 2 wiring
logic inputs
logic inputs output 8 output 4
+10
trim
pad
+10
trim
CH 1
phantom
invert logic
phantom
invert logic
CH 2
levellevellevellevellevellevellevellevel
pad
DA28R
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
INPUTSOUTPUTS
directxfmr
chime
level
send/return
auto mutecompressor
amp
in
pre
out
line
out
rec
out
remote
level
stacking in
+
4
com
8
25V
50V
70V
~
115/230V AC 50/60 Hz 375 VA
BIAMP SYSTEMS
an affiliate of
Rauland-Borg Corp
threshold adjust
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
channel 1channel 2channel 3channel 4channel 5channel 6
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
priority
line
mic
on
off
tel
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
USE ONLY WITH
250V FUSE
+10V c
mute/
chime
60 watt
output
min
out
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
-40
-20
min
max
+ + + + + +
R
C
E158021
R
LISTED 2 Z 91
COMMERCIAL
AUDIO EQUIP
3.15A -230V
6.3A - 115V
directxfmr
chime
level
send/return
auto mutecompressor
amp
in
pre
out
line
out
rec
out
remote
level
stacking in
+
4
com
8
25V
50V
70V
~
115/230V AC 50/60 Hz 375 VA
BIAMP SYSTEMS
an affiliate of
Rauland-Borg Corp
threshold adjust
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
channel 1channel 2channel 3channel 4channel 5channel 6
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
priority
line
mic
on
off
tel
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
USE ONLY WITH
250V FUSE
+10V c
mute/
chime
60 watt
output
min
out
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
-40
-20
min
max
+ + + + + +
R
C
E158021
R
LISTED 2 Z 91
COMMERCIAL
AUDIO EQUIP
3.15A -230V
6.3A - 115V
directxfmr
chime
level
send/return
auto mutecompressor
amp
in
pre
out
line
out
rec
out
remote
level
stacking in
+
4
com
8
25V
50V
70V
~
115/230V AC 50/60 Hz 375 VA
BIAMP SYSTEMS
an affiliate of
Rauland-Borg Corp
threshold adjust
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
channel 1channel 2channel 3channel 4channel 5channel 6
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
phantom pwr
auto mute
manual mute
mute
level
priority
line
mic
on
off
tel
phantom pwr
auto mute
manual mute
mute
level
-40
-20
priority
line
mic
on
off
USE ONLY WITH
250V FUSE
+10V c
mute/
chime
60 watt
output
min
out
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
trim
n
o
m
i
n
a
l
min
max
-40
-20
min
max
+ + + + + +
R
C
E158021
R
LISTED 2 Z 91
COMMERCIAL
AUDIO EQUIP
3.15A -230V
6.3A - 115V
Multi-Floor Office/Hospital Paging System
DA28R
background
music
source
70V
distributed
speaker
system
(Floor #1)
Floor #1
local
paging
mic
70V
distributed
speaker
system
(Floor #3)
Floor #3
local
paging
mic
70V
distributed
speaker
system
(Floor #2)
Floor #2
local
paging
mic
CMA60 (Floor #1)
CMA60 (Floor #2)
CMA60 (Floor #3)
all-call paging
to Floors #1~3
background music
to Floors #1~3
input/output
assignment
all-call paging
background music
all-call paging
background music
CH 1CH 2output 3 output 2 output 1output 7 output 6 output 5
This application shows three CMA60s being used in a multi-floor office/hospital paging system. An all-call paging microphone and a
background music source are connected to an ADVANTAGE
®
DA28R, which distributes those signals independently to the three CMA60s.
Channel #1 of each CMA60 is set for input from line-level all-call paging, and is assigned as a priority channel. Channel #2 of each CMA60
is set for input from the respective floor paging microphone, and is assigned auto muting of -40dB. The push-to-talk switch of each floor
paging microphone is wired to the Mute/Chime terminals of the respective CMA60. Channel #3 of each CMA60 is set for input from line-
level background music, and is assigned manual and auto muting of -20dB. Therefore, local paging will manually mute the background
music only on that floor (-20dB), whereas, all-call paging will automatically mute background music (-20dB) and local paging (-40dB) on all
floors. The CMA60s are set for 'xfmr' output and are connected to 70V distributed speaker systems for each floor.
WARNING: THE ABOVE
DIAGRAM SHOWS THE OUTPUT TERMINAL COVER REMOVED FOR CLARITY ONLY. THE COVER MUST BE INSTALLED WHEN THE UNIT IS ENERGIZED.