Specifications
Technical Support: 877-995-8155 9
WIRING INSTRUCTIONS
Refer to page 17 for terminal layout
SINGLE OPERATOR INSTALLATION:
DUAL OPERATOR INSTALLATION:
PULL TO OPEN
•Connectthered (+) wire of the Phobos actuator
arm to terminal 3 of the Libra control board.
•Connecttheblack (-) wire of the Phobos actuator
arm to terminal 4 of the Libra control board.
•Connectthewhite (FC: Limit Switch) wire of the
Phobos actuator arm to terminal 5 of the Libra
control board.
PUSH TO OPEN
•Connectthered (+) wire of the Phobos actuator
arm to terminal 4 of the Libra control board.
•Connecttheblack (-) wire of the Phobos actuator
arm to terminal 3 of the Libra control board.
•Connectthewhite (FC: Limit Switch) wire of the
Phobos actuator arm to terminal 5 of the Libra
control board.
PULL TO OPEN
•Connectthered (+) wire of the Phobos actuator
arm to terminal 6 of the Libra control board.
•Connecttheblack (-) wire of the Phobos actuator
arm to terminal 7 of the Libra control board.
•Connectthewhite (FC: Limit Switch) wire of the
Phobos actuator arm to terminal 8 of the Libra
control board.
PUSH TO OPEN
•Connectthered (+) wire of the Phobos actuator
arm to terminal 7 of the Libra control board.
•Connecttheblack (-) wire of the Phobos actuator
arm to terminal 6 of the Libra control board.
•Connectthewhite (FC: Limit Switch) wire of the
Phobos actuator arm to terminal 8 of the Libra
control board.
IMPORTANT NOTE: For ease of wiring, the green terminal block sections 3-14, 15-20 & 21-
22 can be detached from the board by pulling them manually away from the base. Ensure
that the power is turned off before attaching and detaching the connectors and that the
terminal blocks are correctly aligned when reconnecting.