Specifications
6 Technical Support: 877-995-8155
LIMIT SWITCH SETTING (PULL TO OPEN)
• Disengage operator with manual release key (D from component list on page 3).
•LocatethelimitsensorslocatedunderthewormdrivecoverasshowninaboveFig.5&6.
•Positionthegateinclosedposition(asshownontopofFig.5).
•Loosenthescrewonthelimitsensorattheendofthearm(asshowninFig.7),closestto
the gate bracket (B from component list on page 3).
•Slidethelimitsensorattheendofthearmuntilyouhearafaint“click”ofthemagnet
catching and then tighten the screw on the limit sensor.
•Loosenthescrewofthelimitsensorclosetothemainbodyoftheoperatorandslideitall
the way backwards (against the main body).
•Manuallymovethegatetoitsfullyopenposition(asshownontopofFig.6)inaslowand
even motion.
•Slidethelimitsensornearesttothemotoruntilyouhearafaint“click”ofthemagnet
catching and then tighten the screw on the limit sensor.
•Manuallymovethegatetoitsfullyclosedposition(asshownontopofFig.5)inaslowand
even motion.
• Reengage the operator with the provided manual release key (part of Kit D from
component list on page 3).
A
B
FIG. 5 FIG. 6
Fig. 5
Fig. 7
Fig. 6