Specifications
4 Technical Support: 877-995-8155
DISENGAGING THE OPERATOR
DISENGAGING THE OPERATOR:
During the installation it is sometimes necessary to disengage the operator using the
provided CLS release key included in kit (D from component list on page 3). Please refer to
drawing below.
CONNECTING CABLES TO THE OPERATOR:
Inordertoprovideexibilityandavoidtheuseofjunctionboxes(pleasecheckwithlocal
electrical requirements if this is allowed) the Phobos BT N and BT NL operators are not
delivered with mounted cables. The kit includes 1 or 2 cables (J from component list on page
3) of 3.3’ each with the following specifications:
3 X 16 AWG stranded wires (E172693) in a weather resistant insulation (J from component list
on page 3).
Note: the cables come with a red sleeve on the green wire on one side. This side is to be
connected to the control board.
Wiring:
1- FC: Connect the white wire for limit switches
2- Motor +: Connect the green wire for operator opening (pull to open)
3- Motor -: Connect the black wire for operator closing (pull to open)
Note: the connectors on the operator must be
closed and sealed with parts contained in
included kit (D from component list on page 3).
Fig. 2
Fig. 1