Specifications
Technical Support: 877-995-8155 17
WIRING DIAGRAM
STROBE LIGHT / MAGNETIC LOCKS CONNECTION
(need to be powered with separate relay Ref: BFT-USS-PAM-2)
24 Vac power supply to accessories
24 Vac power supply to fail safe accessories
(requires dierent wiring – see instruction manual
for further details)
COMMON TERMINAL
START/CLOSE TERMINAL: opens-closes-stops (START) or always closes
(CLOSE) the gate depending upon the logic setting (default is START)
STOP & RESET TERMINAL: stops the gate and UL ALARM when opened
PHOTOEYE TERMINAL: stops the gate when opened, when closed back
continues opening (if gate opening) or reverses (if gate closing)
PHOTOEYE SELF TEST TERMINAL: failure check terminal for PHOTOEYE
terminal (requires dierent wiring – see instruction manual for details)
OPEN TERMINAL: opens the gate when closed (e.g. free exit or
telephone entry contact)
UL ALARM: the contact closes after 2 consecutive obstruction detections
with no limit switch activation. Can be reset by opening the stop
contact or switching o the power supply.
24 Vdc/25 W max
24 Vac OUT (180 mA max)
24 Vac Vsafe OUT (180 mA max)
Note: while the alarm is active
the gate is stopped. Reset the
control board before
re-activating the gate.
Single operator or
operator that moves
rst on opening.
Operator that moves
second on opening.
IMPORTANT NOTE: For ease of wiring, the green terminal block sections 3-14,
15-20 & 21-22 can be detached from the board by pulling them manually away from the
base. Ensure that the power is turned off before attaching and detaching the connectors
and that the terminal blocks are correctly aligned when reconnecting.