Specifications
14 Technical Support: 877-995-8155
CONTROL BOARD QUICK PROGRAMMING
SINGLE OPERATOR SETTING
Only when installing a single actuator (skip in case of dual operator installation):
1. Turn on the display (by pressing twice the “OK” button).
2. Scroll down (“-“ button) to “Logic” menu and press “OK”.
3. The display will show “TCA”. Scroll down to “1 Mot on”. Press “OK”.
4. The display will show “Off”. Press “+”.
5. The display will show “On”. Press “OK”.
6. Switch of the display.
WARNING: When installing a single operator, an improper setting in this logic will lead to
improper function of auto-close feature.
SETTING THE FORCE
1. Turn on the display (by pressing twice the “OK” button).
2. Scroll down (“-“ button) to “Autoset” menu.
The Autoset feature will automatically let the control board learn torques required to correctly
operate the gate.
WARNING: Once “OK” button is pressed the gate will start to move, obstruction detection is
disabled during Autoset. Be sure that no obstacle is within the working range
of the gate while Autoset is being performed.
NOTE: Autoset must be launched from a fully closed position. Autoset run from a different
position may lead to improper control board setting.
3. Press “OK”. The gate will open and close automatically.
4. Once the gate is closed the display will show “OK” (Autoset successful) press “OK” (if “KO”
is displayed, the Autoset failed, usually the cause of it is an improper setting for single
operator installation).
5. Turn off the display.
COMMON SETTINGS
Parameters:
TCA: Timer to close (sec.).
M1 fast time: Working time (sec) at full speed (motor 1) after this time motor 1 will proceed
at slow down speed).
M2 fast time: Working time (sec) at full speed (motor 2) after this time motor 2 will proceed
at slow down speed.
Slow speed: Slow down speed: 3 (25% of full speed)
WARNING! After changing the above parameters (except TCA) an Autoset is required.
Logics:
TCA: Auto close enabled (ON)
3 step: 3 step logic (ON)
Ibl open: Commands during opening ignored (ON).
Photoc. Open: Photocells will be ignored while the gate is opening (ON)
1 mot on: Dual operator installation (OFF), single operator installation (ON).