5.1 Battery Charger
A 230V AC - 9/9.8 V DC Battery Charger is supplied with the Wireless Mini Analyser. The unit can charge 2
rechargeable 9V batteries and includes the following features: LED status display, micro controlling trickle charge
mode, a discharge function, and delta V detection
Intended use:
This product is intended for use only in dry interior rooms.
For use only with rechargeable Ni-Cd and Ni-MH batteries
Failure to follow safety instructions may cause fatal accidents, injuries, and damages to persons and property.
Connecting and operating
1. Connect either one or two PP3 Ni-Cd or Ni-MH batteries into the charging points. Ensure batteries to be
charged are of the same type. Do not mix battery types
2. Plug the Charger into a 230 V AC mains socket, and switch on
3. Select the operation mode with the mode switch: DISHARGE / CHARGE
Note: Discharging is only available at the right charging point.
Display: Red LEDs (CHARGE/READY) Illuminated
Batteries are charging.
Green LEDs (CHARGING/READY) illuminated.
Batteries are fully charged.
Yellow LED (DISCHARGE) illuminated
Batteries are discharging.
The battery can also be charged via the supplied