9 Wireless Analyser Module Specifications
9.1 General
Parameter
Units
Conditions
Min
Typ
Max
Supply Voltage
V
Power supplied to module via Pin 9 on the 9-Way D
Connector or by the Mini USB connector
5
Supply Current
mA
50
9.2 Communications
Parameter
Units
Conditions
Min
Typ
Max
Data Rate
kbaud
19.2
Protocol
2.4GHz IEEE802.15.4 Compatible
Communications Range
m
50
Transmit Power Level
dBm
2.5
Receiver Sensitivity
dBm
-96
9.3 Environmental
Parameter
Units
Conditions
Min
Typ
Max
Operating Temperature Range
°C
-20
70
Lead-Free and RoHS compliant
Compliant with FCC part 15 rules, IC Canada, ETSI ETS 300-328 and Japan ARIB STD T66
FCC ID: TYOJN5139M0
IC: 7438A-CYO5139M0
These modules have been designed to operate with antennas having a maximum gain of 4.4 dBi. Antennas
having a gain greater than 4.4 dBi are strictly prohibited for use with this device. The required antenna
impedance is 50 ohms.