User's Manual

bf1systems IRTPTMS V3 System Description
bf1systems IRTPTMS V3 System Description V1_01
1_01
Page 9 of 15
RD096 110124
7.2.4 Pressure
Pressure overload
Maximum 2000 kPa
Measurement range
50 kPa to 732.5 kPa
7.2.5 Environmental Requirements
Vibration with overlying temperature
Temperature profile
C to 12C
Vibration profile 1
20Hz to 2000Hz: 2 g
2
/Hz to 0.035 g
2
/Hz
Acceleration
Static acceleration (vertical to PCB)
12 x half sine shock pulses of 80g pk acceleration,
pulse width 6ms
Evaluation criteria
No malfunction during and after the test
7.2.6 Mechanical specification
Dimension
70.1mm x 33.4 x 26.8mm
Wheel Sensor Assembly Weight
45g ±1g
7.2.7 Measurement specification
Pressure
Comment
Min
Nom
Max
Units
Measurement range
Nominal
0.882
-
4.631
bar
Accuracy
C to +5C
-29.4
-
+29.4
mbar
Resolution
LSB
-
14.7
-
mbar
Pressure Sensor
Temperature
Comment
Min
Nom
Max
Units
Measurement range
-
-40
-
215
°C
Accuracy
C to +5C
-1
-
+1
°C
Resolution
LSB
-
1
-
°C
IR Sensor Temperature
Comment
Min
Nom
Max
Units
Measurement range
-
-2
-
125
°C
Accuracy
-
-0.5
-
0.5
°C
Resolution
LSB
-
0.125
-
°C