User's Manual

bf1systems IRTPTMS V3 System Description
bf1systems IRTPTMS V3 System Description V1_01
1_01
Page 13 of 15
RD096 110124
Figure 4: RF Antenna dimentions
7.4 Trigger transmitters
7.4.1 Temperature
Operating temperature
-40°C to +10C
Storage temperature
-40°C to + 9C
7.4.2 Mechanical requirements
Dimensions
90.5mm x 65.0mm x 27mm
4 vibration loading capacity
3533 41 202 001 C
Shock loading capacity
3533 41 202 001 C
Free fall
1000 mm falling height, concrete (EN 60068-2-32)
Plug push thru strength
> 55N
Soundness
IP 69K
Pressure balance
Climate membrane 2 mm
7.4.3 Voltage range
Static voltage strength
+20V / -2.8V limited by control unit
Dynamic voltage strength
Interference pulses Type 3a, 3b via coupling clamp
ESD strength
8 kV (human body model)
Operating voltage
+7.0V to +18V
7.4.4 Current consumption
Passive operating current
< 10 mA @ 12V
Active operating current (transmitting)
< 230 mA @ 12V