Specification
(866) 786-1117 • www.BeyondLEDTechnology.com
6
BEYON D
L E D T E C H N O L O G Y
LED CENTER BASKET TROFFERS
KENORA
TM
PANEL / TROFFER
INSTRUCTIONS:
Always turn o the power supply from main circuit breaker rst!
• Recessed Mounting
Figure 1 Figure 2
Carefully unpack unit and properly inspect for defects before installing.
Wear work gloves to prevent dirt and oil from being transferred to the
luminaire. If cleaning is needed, use gloves and a dry cottoncloth. It is
not recommended to use hazardous chemicals.
Lift up four mounting clips on the sides of the luminaire.You can
do it by hand(Do wear work gloves) or use pliers
Insert luminaire into T-bar ceiling grid. Secure safety cable to connection
hole as needed to meet local seismic requirements. Safety cable and method
of attachment to the building provided by contractor according to local
building codes.
Remove electrical enclosure cover. Carefully remove knockout for AC
line input wires and 0-10V control line. Install listed electrical fittings in
the knockout holes for wire protection if needed.
Figure 3 Figure 4
Safety cable hole
Plug in AC line(L and N,and GND) to the LED Driver using 18-14AWG
Wire. When connecting 0-10Vdimming controller, wires must run through a
separate knockout hole equipped with an appropriate electrical fitting.
Follow wire connection instructions.When using the 0-10V dimming
controller Run wires from controller through a different knockout than
the AC input wire. Don t forget to return the electrical enclosure cover
and tighten the screws.
Figure 6
AC line
Gnd
ACL
ACN
Dim +
LED +
Dim -
LED -
LED Driver
Green
Black
White
To 0-10V
Dimmer
Figure 5
To 0-10V
Dimming
controller
AC line