Specification
Test Condition:
Luminous Intensity Distribution Diagram:
Test Ambient (°C)
Test Humidity (%)
Orientation
Stabilization Time (minute)
Test Time (minute)
25.1 44.3 Face Down 90 25
Electrical Data:
Voltage (V) Frequency (Hz) Current (A) Wattage (W) Power Factor
120.0 60 2.5476 305.34 0.9988
Goniophotometer Data:
Parameter Results
Total Luminous (lm) 46689.2
Luminous Efficacy (lm/W) 152.91
Zonal Lumens Distribution (0-90°)
99.9%
Zonal Lumens Distribution (80-90°)
1.7%
Beam Angle (°) 91.3
BUG B4-U2-G4
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,164.2
UNIT:cd
C30/210,65.2
UNIT:cd
C60/240,67.8
UNIT:cd
C90/270,66.0
AVERAGE BEAM ANGLE(50%):90.8 DEG
0
2000
4000
6000
8000
10000
(866) 786-1117 • www.BeyondLEDTechnology.com