Test Condition:
Test Ambient (°C) Test Humidity (%) Orientation Stabilization Time (minute) Test Time (minute)
25.0 43.6 Face Down 90 25
Electrical Data:
Voltage (V) Frequency (Hz) Current (A) Wattage (W) Power Factor
120.0 60 1.2361 148.17 0.9989
Goniophotometer Data:
Parameter Results
Total Luminous (lm) 23129.6
156.10
99.9%
1.7%
Beam Angle (°) 90.8
BUG B3-U2-G3
Luminous Intensity Distribution Diagram:
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,164.2
UNIT:cd
C30/210,65.2
UNIT:cd
C60/240,67.8
UNIT:cd
C90/270,66.0
AVERAGE BEAM ANGLE(50%):90.8 DEG
0
2000
4000
6000
8000
10000
BLUE
TM
(866) 786-1117 • www.BeyondLEDTechnology.com
