Specification
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
Method(Self-absorption):
Parameter
Result
Special Color Rendering Indices
Test Voltage (V)
120
R1
78
R9
0
Frequency (Hz)
60
R2
90
R10
77
CCT (K)
2942
R3
96
R11
75
Duv
-0.0011
R4
77
R12
68
Chromaticity (x, y)
x=0.4395 y=0.4023
R5
78
R13
81
Chromaticity (u’, v’)
u'=0.2530 v'=0.5211
R6
87
R14
98
Color Rendering Index (CRI)
80
R7
80
R15
70
R9
0
R8
54
--
--
Photometric Measurement - Sphere-Spectroradiometer Method:
Parameter
Results
DLC V4.4 Pass Criteria
Test Voltage (V)
120
277
--
Frequency (Hz)
60
60
Total Luminous (lm)
8265
8323
>=375 lm/ft (-10%)
Luminous Efficacy (lm/W)
135.43
137.82
Standard: >=
Premium: >=
105(-3%)
130(-3%)
Distribution Diagram
Chromaticity Measurement - Sphere-Spectroradiometer