Report No.: ELC1905042E-D
Laboratory: Belling Test Laboratory Co., LTD A2LA Certificate# 4810.01
Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, Peoples Republic of China. Website: http://www.bltst.com
Report Format Number BL-FM-SA-012
6 / 18
2.2 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction BL-QP-033)
Test date
2019-06-07
Test Ambient:
25.2 º C
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
AST-PG05B-75WAT2A1-abc40
(tested at 50% CCT setting)
Electrical Measurement:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
ELC1905042
E-D2
120.0
60
0.6091
72
0.985
14.22
277.0
60
0.2916
71.64
0.887
16.05
DLC Pass Criteria
>= 0.9(-3%)
<= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:
Parameter
Result
Special Color Rendering Indices
Test Voltage (V)
120.0
R1
82
R9
10
Frequency (Hz)
60
R2
91
R10
79
CCT (K)
3861
R3
96
R11
80
Duv
-0.00150
R4
81
R12
63
Chromaticity (x, y)
x=0.3856 y=0.3767
R5
83
R13
85
Chromaticity (u, v)
u(u')=0.2285 v'=0.5023
R6
88
R14
98
Color Rendering Index (CRI)
83.6
R7
84
R15
76
R9
10
R8
63
--
--
Photometric Measurement Goniophotometer Method:
Parameter
Result
DLC V4.4 Pass Criteria
Test Voltage (V)
120.0
277.0
--
Frequency (Hz)
60
60
Total Luminous (lm)
10485.0
10239.6
>=10000(-10%)
Luminous Efficacy (lm/W)
145.63
142.93
Premium: >= 120(-3%)
Most worst Luminous/Highest Watts
142.22
Zonal lumens in the 60-80° zone (%)
30.3
--
>=30(-3)
Zonal lumens in the 70-80° zone (%)
11.2
25(+3)
Beam Angle (°)
113
--
--
Center Beam Candle Power (cd)
2393
--
--