Installation Guide
Report No.: ELC1905042E-D
Laboratory: Belling Test Laboratory Co., LTD A2LA Certificate# 4810.01
Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.com
Report Format Number BL-FM-SA-012
4 / 18
2.1 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction BL-QP-033)
Test date
2019-06-07
Test Ambient:
25.2 º C
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
AST-PG05B-75WAT2A1-abc30
(tested at 0% CCT setting)
Electrical Measurement:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
ELC1905042
E-D1
120.0
60
0.6054
72.14
0.993
14.31
277.0
60
0.2847
71.53
0.907
16.14
DLC Pass Criteria
>= 0.9(-3%)
<= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:
Parameter
Result
Special Color Rendering Indices
Test Voltage (V)
120.0
R1
80
R9
6
Frequency (Hz)
60
R2
91
R10
79
CCT (K)
2969
R3
96
R11
79
Duv
-0.00057
R4
80
R12
70
Chromaticity (x, y)
x=0.4383 y=0.4031
R5
81
R13
83
Chromaticity (u’, v’)
u(u')=0.2519 v'=0.5212
R6
89
R14
99
Color Rendering Index (CRI)
82.2
R7
81
R15
73
R9
6
R8
58
--
--
Photometric Measurement – Goniophotometer Method:
Parameter
Result
DLC V4.4 Pass Criteria
Test Voltage (V)
120.0
277.0
--
Frequency (Hz)
60
60
Total Luminous (lm)
9146.6
8876.6
5000-10000(-10%)
Luminous Efficacy (lm/W)
126.79
124.10
Premium: >= 115(-3%)
Most worst Luminous/Highest Watts
123.05