Use and Care Manual
Page 6 of 015 Report No.: BL17120001-1
Shenzhen Belling Efficiency Testing Lab
Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com
3.2 Goniophotometer System
3.2.1 Electrical data
Model Number
Input Voltage(V)
Frequency (Hz)
Input Current (A)
Power (W)
SNC-CP-150W-231X-1601
4000K
120
60
1.2210
145.5
277
60
0.5487
141.8
SNC-CP-150W-231X-1601
5700K
120
60
1.2273
146.1
Test Item
Model
Test Voltage (V)
Frequency
(Hz)
Test Result
Power factor
SNC-CP-150W-231X-1601
4000K
120
60
0.993
277
60
0.933
SNC-CP-150W-231X-1601
5700K
120
60
0.992
277
60
0.993
Total harmonic
distortion, %
SNC-CP-150W-231X-1601
4000K
120
60
10.59
277
60
14.72
SNC-CP-150W-231X-1601
5700K
120
60
10.11
277
60
14.61
Off state power
(W)
--
--
--
--
--
--
--
--
3.2.2 Photometric data
Model Number
Input
Voltage(V)
Luminous
Flux (lm)
Efficacy
(lm/W)
Zonal Lumen in
0-40°(%lm)
Zonal Lumen in
40-70°(%lm)
SNC-CP-150W-231X-
1601 4000K
120
14866.5
102.18
45.4
47
277
14788.6
104.30
--
--
SNC-CP-150W-231X-
1601 5700K
120
15611
106.85
--
--
3.2.3 Calculated Efficacy Data for family models (4500K and 5000K):
Model Number
Luminous Flux
(lm)
Power
(W)
Efficacy (lm/W)
SNC-CP-150W-231X-1601 4000K
14866.5
145.5
102.18
SNC-CP-150W-231X-1601 4500K
15052.6
145.65
103.35
SNC-CP-150W-231X-1601 5000K
15238.8
145.80
104.52
SNC-CP-150W-231X-1601 5700K
15611
146.1
106.85