Instructions / Assembly
Bay Area Compliance Laboratories Corp. (Dongguan)
No.69, Pulongcun, Puxinhu Industrial Area Tangxia ,
Dongguan, Guangdong, China.
The IAS Accreditation Number TL-460
Report No. R2DG181011050-10
Page 6 of 13
2 - Summary of Test Result
Data Set:
Sample
Size
Failures
Observed:
Test
Interval
Test
Duration
α:
β:
Reported TM-21
L
70
Lifetime
Reported TM-21
L
90
Lifetime
1
25
0
1000hrs
9000hrs
2.055E-06
1.000
>54000 hours
51000 hours
2
25
0
1000hrs
9000hrs
2.824E-06
1.000
>54000 hours
37000 hours
Average Lumen Maintenance (Percentage of Initial Luminous Flux)
Data Set:
1000hrs
2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
1
99.98%
99.74%
99.48%
99.23%
98.98%
98.72%
98.60%
98.42%
98.17%
2
99.78%
99.50%
99.22%
98.93%
98.64%
98.34%
98.09%
97.82%
97.53%
Average Chromaticity Shift
Data Set:
1000hrs
2000hrs
3000hrs
4000hrs
5000hrs
6000hrs
7000hrs
8000hrs
9000hrs
1
0.0003
0.0006
0.0009
0.0012
0.0014
0.0017
0.0020
0.0022
0.0025
2
0.0005
0.0008
0.0010
0.0014
0.0016
0.0019
0.0022
0.0025
0.0028
Average Lumen Maintenance and Chromaticity Shift VS. Time
0.0000
0.0005
0.0010
0.0015
0.0020
0.0025
0.0030
0.0035
0.0040
70%
75%
80%
85%
90%
95%
100%
105%
110%
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Chromaticity Shift (Du'v')
% Luminous Flux
Time (hours)
Data Set 1 Flux Data Set 2 Flux
Data Set 1 ∆u'v' Data Set 2 ∆u'v'